ABOUT THIS PRODUCT

With TTF200 and TTF300 field-mount temperature transmitters, ABB offers cost-effective solutions for both standard applications and applications that are more demanding. A version with stainless steel housing allows it to be used in harsh ambient conditions at temperatures down to –50 °C (–58 °F). The devices are available with an indicator, which optionally also allows configuration on site without additional handheld terminal. Sensor redundancy, sensor drift monitoring and freestyle characteristic are available. The TTF300 comes with an optional wireless model, the TTF300-W.

PRODUCT DETAILS

TTF200

  • Field Mountable
  • One Sensor Input
  • Resistance thermometers, resistance-type remote sensors (0 to 5000 Ohm)
  • Thermocouples, voltages, mV-voltages (–125 to 1100 mV)
  • Pt100, two-wire, three-wire, four-wire, thermocouple with internal reference junction
  • Continuous sensor monitoring and self-monitoring
  • Supply voltage monitoring
  • Wire break and corrosion monitoring
  • Sensor error adjustment
  • Electrical isolation
  • Transmitter-controlled graphical indicator
  • LCD indicator for process value, sensor value and actual value
  • HART Configurable

TTF300

  • Wireless option available
  • Field mount, single-compartment housing, two cable glands
  • Two sensor inputs
  • Resistance thermometers, resistance-type remote sensors (0 to 5000 Ohm)
  • Thermocouples, voltages, mV voltages (–125 to 1100 mV)
  • Pt100, two-wire, three-wire, four-wire, thermocouple with internal reference junction
  • 2x Pt100 two-wire and three-wire, 2x thermocouple or 1x Pt100 two-wire, three-wire, four-wire and 1x thermocouple
  • Continuous sensor monitoring and self- monitoring
  • Supply voltage
  • Wire break and corrosion monitoring
  • Sensor error adjustment
  • Electrical isolation
  • Specific linearization
  • Callendar-Van Dusen coefficient, value pair table / 32 points
  • Transmitter-controlled, graphical LCD indicator with dual function
  • Configuration of the transmitter via buttons
  • Process, sensor and actual values display
  • HART Configurable

Example Configuration

TTF300.L3.C.2.H.BS.K2.T0.M5

TTF300: Field mounted, Pt100 (RTD), thermocouples, electrical isolation
• L3: Explosion protection- FM Explosion Proof (XP): XP, DIP, Class I, II, III, Div. 1+2, Groups A-G, factory sealed
• C: Housing/display- single-compartment housing (aluminum) / with LCD display HMI
• 2: Cable entry- thread 2 x 1/2″ NPT (National Pipe Thread)
• H: Communication protocol- HART, programmable, output signal 4-20mA
• BS: Configuration- standard
• K2: Mounting bracket- wall mounting / 2” pipe mounting bracket (stainless steel)
• T0: Device identification plate- plate stainless steel
• M5: Documentation language- English

DOCUMENTS